Thermal insulation sealing strips play a role in reducing heat exchange and blocking air infiltration in doors, windows, and equipment. Whether the installation is in place and the maintenance is timely will affect its actual performance and service life. Below are several noteworthy details from three aspects: preparation before installation, installation process, and maintenance inspection.
1、 Preparation before installation
Before installation, the groove and contact surface should be cleaned to remove dust, oil stains, and old adhesive residue, and kept dry and clean. If there is deformation or burrs in the groove, it can be adjusted appropriately to avoid affecting the insertion of the rubber strip. Check if the specifications of the rubber strip match the size of the groove, and if the cross-sectional shape can be smoothly inserted. If the ambient temperature is low, the rubber strip may become too hard. It can be left at room temperature for a period of time in advance, and then operated after it returns to softness to reduce the risk of cracking.
2、 Key points during installation process
When embedding the rubber strip, it is advisable to apply force evenly in sections to avoid local thinning or breakage caused by single point strong pulling. A small margin can be reserved in length to cope with shrinkage, but it should not be too long, otherwise wrinkles may accumulate at the corners. When encountering a corner position, you can slow down to ensure that the rubber strip fits the contour, and if necessary, make small sections for fixation. If both inner and outer rubber strips need to be installed simultaneously, the inner side can be treated first, and then the outer side can be adjusted. Avoid using sharp tools to pry the rubber strip directly during installation to prevent damage. For the equipment door body, it is also necessary to confirm that the direction of the rubber strip is consistent with the closing direction to ensure uniform force when closing the door.
3、 Inspection after installation
After installation, you can press along the direction of the rubber strip section by section to check for any warping, groove detachment, or obvious gaps. Observe whether the adhesive strip is evenly adhered to the frame, glass or equipment door, and whether the corners are smooth. If local looseness is found, it can be re embedded or adjusted appropriately. The outer rubber strip also needs to confirm that the drainage channel is not blocked to avoid water accumulation affecting the sealing effect.
4、 Daily maintenance tips
It is recommended to regularly check the rubber strip for signs of aging, hardening, cracking, or shrinkage, clean the surface dust, and keep the groove drainage unobstructed. Avoid using strong acid and alkali cleaning agents to wipe directly, in order to avoid accelerating material aging. If the rubber strip shows significant loss of elasticity or frequent groove detachment, replacement may be considered.
Overall, the installation of insulation sealing strips focuses on thorough cleaning, even application of force, and meticulous inspection, while maintenance is important in a regular and moderate manner. Following standardized procedures can help to achieve its intended sealing and insulation effects.